High Country Tek emc-3L User Manual
Page 46
Single Coil Low Side
Name Description
Range
(Low-Side/PWM) Name
Set or test the state Current Target or
Process in percentage of min to max
current 0 = 0 Current, .1% = Min Current,
and 100% = Max Current
0% to 100%
Name.Enable
Set the PWM to 0 or enable the PWM
True [PWM Enabled], False [PWM =
0]
Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil Short]
Name.Open
Get the Coil Flag for Open Status
Off [Coil Ok], On [Coil Open]
Name.Rampup
Set the ramp up rate (time to travel from
0% to 100%)
0.0 to 65.00 s
Name.Rampdown
Set the ramp down rate (time to travel
from 100% to 0%)
0.0 to 65.00 s
Name.Frequency
Set PWM frequency
0 to 1000 for 0 to 100hz
Name.Dutycycle
Ser PWM dutycycle
0 to 1023 for 0 to 100%
Name.Freqerror
Returns error 0 = No Error 1 = Frequency
error, 2 means duty cycle error
HSEvenName
Set the Bang-bang Coil to On or Off
Off, On
HSEven#Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil Short]
HSEven#Name.Open
Get the Coil Flag for Open Status
Off [Coil Ok], On [Coil Open]
HSOddName
Set the Bang-bang Coil to On or Off
Off, On
HSOdd#Name.OpenDisable Set the Disable Coil Open Detection
0 [Enabled], 1 [Disabled]
HSOdd#Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil Short]
HSOdd#Name.Open
Get/Set the Coil Flag for Open Status
Off [Coil Ok], On [Coil Open]
Name.Cur
Current actual * CurGain = amps
0 – 3.5 amps
Name.RampCur
Current ramped Currend*CurGain= amps 0 – 3.5 amps
Name.CurErr
Current Error = RampCur – Cur
16 Signed Integer
Name.CurSumErr
Current Error accumulated over time
0 – 65535
Name.CurP
Current Proportional Term Constant “P”
0 – 255
Name.CurI
Current Proportional Term Constant “I”
0 – 255
Name.MinCurA
Minimum Current Coil A *.001 = amps
0 – 3.5 amps
Name.MaxCurA
Maximum Current Coil A *.001 = amps
0 – 3.5 amps
Name.Config
Configuration Word – Output, Process,
Coil
0 = DCHS, 1 = SCHS, 3 = SCLS
P/N: 021-00163, Rev. A.0 - for V5.2 Tools
Page | 46