Digital Inputs
Name Description
Range
Name
Set/Get the state of the switch
False or Off, True or On
Name.RealRPM
The Unsigned Integer Value of the RPM.
For Pulse inputs Only
0 to 9999
Name.PulseTimeout
Get/Set Pulse Timeout for Loss of Signal
0 to 65535
Name.PulsesPerRev
Get/Set Pulses Per Revolution
0 to 9999
Name.Counter
Get/Set Unsigned Integer Value of the
Counter. Pulse inputs Only
0 to 65535
Name.LOS
Loss of Signal flag set after time out. For
Pulse inputs Only
False (Pulses ok), True (No Pulse
Input)
High Side Only
Name Description
Range
HSEvenName
Set the Bang-bang Coil to On or Off
Off, On
HSEven#Name.OpenDisable Set the Disable Coil Open Detection
0 [Enabled], 1 [Disabled]
HSEven#Name.Short
Get the Coil Flag for Short Status
Off [Coil Ok], On [Coil Short]
HSEven#Name.Open
Get the Coil Flag for Open Status
Off [Coil Ok], On [Coil Open]
HSOddName
Set the Bang-bang Coil to On or Off
Off, On
HSOdd#Name.OpenDisable
Set the Disable Coil Open Detection
0 [Enabled], 1 [Disabled]
P/N: 021-00163, Rev. A.0 - for V5.2 Tools