High Country Tek emc-3L User Manual
Page 42
Universal and Analog Inputs
Name Description
Range
Name
Get 0 to 100% regardless of direction
0% to 100%
NameLo
Get 0 to 100% of Min to (Center -
Deadband) only if Center is enabled
0% to 100%
NameHi
1
Get 0 to 100% of (Center + Deadband)
to Max only if Center is enabled
0% to 100%
Name.Dir
Get the Upper or Lower Side of the
Analog Input only if Center is enabled.
False (Lower Side), True (Upper Side)
Name.RawVolts
Volts or mAmps (ma = universal input
ma select)
0 to 1023 * Scale
†
Name.RefVolts
Reference Volts = RefVolts * .00489
0 to 1023
Name.RampVolts
Ramped Volts = RampVolts * Scale
Factor
0 to 1023 * Scale
†
Name.MinVolts
When Name = 0% (i.e. Center not
enabled)
0 to 1023 * Scale
†
Name.MaxVolts
When Name = 100%
0 to 1023 * Scale
†
Name.MinLimit
Threshold for Name.MinF
0 to 1023 * Scale
†
Name.MaxLimit
Threshold for Name.MaxF
0 to 1023 * Scale
†
Name.RefMinLimit
Threshold for Name.MinRF
0 to 1023 * Scale
†
Name.RefMaxLimit
Threshold for Name.MaxRF
0 to 1023 * Scale
†
Name.CenterVolts
Where Center Volts
0 to 1023 * Scale
†
Name.Deadbandv
Plus and minus volts about CenterVolts
0 to 1023 * Scale
†
NameX
Where NameX = NameLo, NameHi if
Center is enabled NameX = Name if
Center is not enabled
Name.MinF
Status Flag set if Voltage is less than
Min Limit
False (ok), True (Outside Limit)
Name.MaxF
Status Flag set if Voltage is greater than
Max Limit
Range: False (ok), True (Outside Limit)
Name.MinRF
Status Flag set if Voltage is less than
Reference Min Limit
False (ok), True (Outside Limit)
Name.MaxRF
Status Flag set if Voltage is greater than
Reference Max Limit
False (ok), True (Outside Limit)
Name.LOS
Loss of Signal flag set after time out.
For Universal Pulse inputs Only
False (Pulses ok), True (No Pulse
Input)
Name.RealRPM
The Unsigned Integer Value of the RPM.
For Universal Pulse inputs Only
0 to 9999
Name.Counter
Get/Set Unsigned Integer Value of the
Counter. Universal Pulse inputs Only
0 to 65535
Name.PulsesPerRev
Get/Set Pulses Per Revolution
0 to 9999
†
Scale depends on Input Range (0 to 5 =.00489, 0 to 10 = .00977, 0 to 25ma = 0.02158 )
P/N: 021-00163, Rev. A.0 - for V5.2 Tools
Page | 42