configuration for all of the system inputs and outputs and is loaded along with the .PGM file by the Program
Loader Monitor
Note: .MEM files contain all of the DVC710’s physical information. If changes are made to the DVC
3.6 electing or Changing Your Project Type
configuration with the Program Loader Monitor, you can update the DVC program with the new configuration
data by doing the following. Using the Program Loader Monitor, save a new .MEM file by clicking on "Export to
File". Using the Programming Tool, open your project and click "File" and select "Load Mem File". Select the
.MEM file and click Open. The program will automatically update all of the DVC physical information.
S
you can select from amongst two project types. These are:
3.7 Programming the DVC710
Using the Project Menu of the Project window
• DVC710
• DVC7
ware features are very
ital Inputs, Analog Inputs
tions
o configure the module, access each of the features
he following subsections give the definitions of each
dow.
3.8
The DVC hardware and firm
flexible and support many input and output
configurations and relationships. For quick reference
the inputs and outputs have been grouped into the
following:
• Dig
• Universal
Inputs
• Output
Groups
• Input / Output Func
T
by clicking on their associated buttons. The buttons
are aligned vertically underneath each group name.
Click on a button to access the configuration options
for that input or output.
T
of the fields accessible in the DVC710 configuration win
Program Name and Passwords
DVC710 Configuration and Setup Screen
Program Name:
When the application executes, the Program Loader Monitor will display the program name.
end Password:
Range: 16 Characters.
S
Allows access to EEmem and other I/O settings from the Program Loader Monitor, will not
pp Password:
Level 1 Password –
allow the user to load programs or BIOS.
Range: 16 Characters.
A
– Allows all Password Level 1 access plus allows the user to load applications. Restricts the
Level 2 Password
user from loading a new BIOS.
Range: 16 Characters.
P/N: 021-00163, Rev. A.0 - for V5.2 Tools