Electrical connections – Vaisala PTB220 User Manual
Page 44

U
SER
'
S
G
UIDE
_______________________________________________________________________
38 ___________________________________________________________________ M210194
EN
-A
120
65
133
145
104
120
ø6.5
F
IGURE
5-1
Dimensions and mounting positions of PTB220
barometers
Electrical connections
In barometers with RS232C/TTL level serial/pulse interface the pin
assignment is as follows:
1
2
3
4
5
6
7
8
9
F
IGURE
5-2
9-pin female subD-connector
T
ABLE
5-1
Pin assignment for RS 232C/TTL serial/pulse output
PIN
SIGNAL
1
TX with diode
2
TX/TXD/TXD inverted
3
RX/RXD/RXD inverted
4
external power on/off control
5
ground for the RS 232C
6
pulse output (TTL level)
7
ground for supply voltage and TTL level serial
interface and pulse output
8
pulse trigger
9
supply voltage (10...30 VDC)
In barometers with RS 232C/485/422 serial interface the pin
assignment is as follows:
- DM500 (138 pages)
- DM70 (93 pages)
- DMT132 (74 pages)
- DMT143 (76 pages)
- DMT152 (70 pages)
- DMT242 (4 pages)
- DMT340 (191 pages)
- DMT345 (185 pages)
- DPT145 (63 pages)
- DPT146 (71 pages)
- PTU300 (217 pages)
- PTB330TS (89 pages)
- PTB220 (10 pages)
- PTB330 (144 pages)
- PTU200 (64 pages)
- PTU200MIK1 (18 pages)
- SPH10 (2 pages)
- SPH20 (2 pages)
- PTB110 (4 pages)
- PTB200 (30 pages)
- PTB210 (analog) (27 pages)
- PTB210 (serial) (32 pages)
- GM70 (68 pages)
- GMD20 (4 pages)
- GMK220 (18 pages)
- GML20 (2 pages)
- GML20T (2 pages)
- GMM20W (5 pages)
- GMM220 (6 pages)
- GMP231 (2 pages)
- GMP231 (90 pages)
- GMP343 (94 pages)
- GMR20 (2 pages)
- GMT220 (42 pages)
- GMW90 (101 pages)
- XMW90 (4 pages)
- MM70 (67 pages)
- MM70 (71 pages)
- MMT162 (66 pages)
- MMT310 (81 pages)
- MMT330 (181 pages)
- MMT330 (171 pages)