DAVIS Vantage Pro Console User Manual
Page 58
![background image](/manuals/405937/58/background.png)
Appendix B: Specifications
Outside
Temperature
b
ISS, Temp Station or
Temp Hum Station
0.1
°F; 0.1°C
-40 to +150
°F; -40°
to +65
°C
1
°F; 0.5°C
Extra Temperature
ISS, Temp Station,
Temp Hum Station,
Leaf Soil Station or
Soil Station
1
°F; 1°C
-40 to +150
°F
-40
° to +65°C
1
°F (0.5°C)
Heat Index
ISS or Temp/Hum
Station
1
°F; 1°C
-40 to +135
°F;
-40
° to +57°C
3
°F (1.5°C)
Temp-Hum-Sun-
Wind index
(THSW)
ISS & Solar
Radiation
1
°F; 1°C
-90 to +135
°F;
-68
° to +64°C
4
°F (2°C)
Time
Included in Console
1 min
24 hours
8 sec/mon
Date
1 day
month/day
8 sec/mon
UV Index
UV Radiation
0.1 Index
0 to 16
5% of full scale
UV Dose
0.1 MED < 20, 1
MED > 20
0 to 199 MEDs
5%
Wind Direction
Anemometer
1
°
0 to 360
°
7
°
Compass Rose
22.5
°
16 compass pts
0.3 compass pt
Wind Speed (large
cups)
1 mph; 1 kt; 0.5 m/s;
1 km/h
2 to 150 mph;
2 to 130 kts
3 to 241 km/h,
1 to 68 m/s
greater of
2 mph/kts;
1 m/s; 3 km/h
or 5%
Wind Speed (small
cups)
1 mph; 1 kt; 0.5 m/s;
1 km/h
3 to 175 mph;
3 to 150 kts
1.5 to 79 m/s
5 to 282 km/h
greater of
3mph; 3 kts;
1 m/s; 5km/h
or 5%
Wind Chill
ISS
1
°F; 1°C
-120
° to +130°F
-84
° to +54°C
2
° F;1°C
a Barometric pressure readings are standardized to sea level. The range displayed is for the standardized value.
The console can be set to standardize readings within an elevation range of -1500 to +12,500 (-460 to + 3810
m); however, the console screen limits selection and display of lower elevation to -999’ when using feet as
elevation unit.
b Solar radiation induced error for standard radiation shield: +4°F (2°C) at solar noon; for fan-aspirated radiation
shield: +0.6°F (0.3°C) at solar noon (insolation = 1040 W/m
2
, avg. wind speed
≤ 2 mph (1 m/s), reference: RM
Young Model 43408 Fan-Aspirated Radiation Shield)
.
T
ABLE
3-1: W
EATHER
D
ATA
S
PECIFICATIONS
Variable
Required Sensors
Resolution
Range
Nominal Accuracy
(+/-)