beautypg.com

HP StorageWorks XP Remote Web Console Software User Manual

Page 85

background image

NOTE:

To change group options, split all pairs in the group first.

Figure 45 CT Group Option pane

MCU-RCU Path: Selected port type for remote copy connections. You cannot change the port
type on the CT Group Option pane.

Time Out (Copy Pending) (min.): Maximum delay (copy pending timeout) allowed for XP
Continuous Access Async copy (none or from 1 to 15 minutes; none = no timeout for XP
Continuous Access Async copy pending). The default is five minutes. If the delay between the
XP Continuous Access Async P-VOL update and corresponding S-VOL update reaches the
specified time, the RCU suspends all S-VOLs in the group. A timeout occurs when the RCU
cannot settle a recordset within the specified time or has not had any communications from
one of the MCUs in the group within the specified time.

NOTE:

The copy pending timeout value should be less than the I/O timeout value of the

host system.

Time Out (RCU Ready) (min.): Maximum delay allowed for re-establishing MCU-RCU
communications following MCU power-off (none or from 1 to 10 minutes; none = no timeout
for XP Continuous Access Async RCU ready). The default is five minutes. If the MCU cannot
re-establish communications with the RCU within the specified time, the MCU suspends all
P-VOLs in the group.

Cancel button: Cancels settings.

Set button: Sets consistency group options.

1.

Connect to the MCU.

2.

Split all pairs in the group (Pairsplit-r).

3.

From the Consistency Group tree, click a consistency group mode that includes the consistency
group to be modified.

4.

From the Consistency Group list, click the consistency groups to be modified. Select more than
one consistency group with MCU in the This CU column.

5.

Right-click, click CT Group Operation, and click CT Group Option. The CT Group Option pane
appears. If the CT Group Option command is not enabled, split the remaining pairs in this
consistency group.

6.

Change group options as needed.

7.

Click Set in the CT Group Option pane. The CT Group Option pane closes, and the list changes
to the Consistency Group Settings Parameter list. Settings are applied to the list.

NOTE:

After being set, options can be modified and canceled (see

“Modifying parameters

and deleting consistency groups” (page 88)

).

8.

Click Apply on the XP Continuous Access main pane to apply settings to the disk array.

XP Continuous Access Asynchronous operations

85