HP StorageWorks XP Remote Web Console Software User Manual
Page 74
![background image](/manuals/398622/74/background.png)
5.
In the pop-up menu, click RCU Operation, and click Add RCU. The Add RCU pane appears.
6.
Enter the RCU's S/N and the CU image's Controller ID, CU number, and SSIDs or Path Gr.
ID. Enter the value in hexadecimal within the range of 1 to FF for Path Gr. ID or use the default
value. Up to 64 Path Gr. IDs can be registered per subsystem. The MCU verifies the S/N
when paths are established, and verifies the SSIDs when volume pairs are created. If needed,
add and delete SSIDs later using the Add SSID pane (see
Adding and deleting SSIDs for RCUs
).
7.
Click the MCU and RCU ports from the drop-down lists. The MCU will not establish less than
the minimum number of paths as specified on the RCU Option pane (see
). If needed, you can add and delete paths later by using the
Add Path pane (see
Adding and deleting logical paths for RCUs (Add Path/Delete Path)
).
8.
Click Option to open the RCU Option pane. Click Cancel to cancel settings made on the Add
RCU pane.
9.
From the RCU Option pane, enter or select the settings for Minimum Paths, Maximum Initial
Copy Activity, and RIO MIH Time. For Fibre Channel interface, also specify the Path Blockade
Watch setting.
10. In the RCU Option pane, click Set (even if you made no changes). Click Cancel to cancel the
settings. The list changes to the RCU Settings Parameter list.
11. The new RCU is displayed in the RCU Settings Parameter list. To check the path status for this
RCU, select the RCU, right-click, and click RCU Status. For more information about path status,
see the Troubleshooting chapter of the HP StorageWorks XP Command View Advanced Edition
Software Device Manager user guide or the HP StorageWorks XP Remote Web Console user
guide: HP XP12000 Disk Array, HP XP10000 Disk Arry, HP 200 Storage Virtualization System.
NOTE:
After being set, options can be modified and canceled (see
).
When the pair option is set (the RCU Option pane is closed), the list changes to the RCU Settings
Parameter list.
shows the items in the RCU Settings Parameter list.
Figure 35 RCU Settings Parameter list
•
S/N: RCU serial number
•
SSID 1 to SSID 4: Selected SSID: SSID 1 to SSID 4
•
M-R Path: Channel type
•
Num. of Path: Number of the paths used
•
MCU Port 1 to MCU Port 8: Port number on the MCU side: 1 to 8
•
RCU Port 1 to RCU Port 8: Port number on the RCU side: 1 to 8
•
Min.Path: Minimum number of paths required for each RCU connected to the current MCU
•
Activity: Number of concurrent initial copy operations
•
MIH Time: Time value for the remote I/O (RIO) missing interrupt handler (MIH)
•
Path Watch: Time for monitoring blockade in the Fibre Channel paths on the MCU side
74
Performing XP Continuous Access configuration operations