beautypg.com

Replacing the failed component, Returning the defective part, Replacing a disk drive – HP 3000 Enterprise Virtual Array User Manual

Page 87: Before you begin

background image

Replacing the failed component

CAUTION:

Components can be damaged by electrostatic discharge. Observe the following proper anti-static

protection:

Always transport and store CRUs in an ESD protective enclosure.

Do not remove the CRU from the ESD protective enclosure until you are ready to install it.

Always use ESD precautions, such as a wrist strap, heel straps on conductive flooring, and an ESD

protective smock when handling ESD sensitive equipment.

Avoid touching the CRU connector pins, leads, or circuitry.

Do not place ESD generating material such as paper or non anti-static (pink) plastic in an ESD

protective enclosure with ESD sensitive equipment.

HP recommends waiting until periods of low storage system activity to replace a component.

When replacing components at the rear of the rack, cabling may obstruct access to the

component. Carefully move any cables out of the way to avoid loosening any connections. In

particular, avoid cable damage that may be caused by:
• Kinking or bending.
• Disconnecting cables without capping. If uncapped, cable performance may be impaired by

contact with dust, metal or other surfaces.

• Placing removed cables on the floor or other surfaces, where they may be walked on or

otherwise compressed.

Replacement procedures are provided with each component. You can also download the

replacement instructions in Dutch, English, French, German, Italian, Spanish and Japanese from

the following web sites:

http://www.hp.com/go/eva4000

http://www.hp.com/go/eva6000

http://www.hp.com/go/eva8000

From any of these web sites, select Technical documents under Product information for additional

information.

Returning the defective part

HP specifies, in the materials shipped with a replacement CSR part, whether the defective

component must be returned to HP. Where required, you must ship the defective component back

to HP within a defined period of time, normally five (5) business days. The defective component

must be returned with the associated documentation provided in the shipping material. Failure

to return the defective component may result in HP billing you for the replacement. With a

customer self repair, HP will pay all shipping and component return costs and determine the

courier/carrier to be used.

Replacing a disk drive

This section describes the procedure for replacing a Fibre Channel disk drive.

Before you begin

Observe the following precautions when replacing the disk drive.

Enterprise Virtual Array 3000/5000 user guide

87