Drive enclosure emu, Controls and displays, 12 power supply/blower status indicators – HP 3000 Enterprise Virtual Array User Manual

Page 51: Table 12

background image

Table 12 Power supply/blower status indicators

Blower status

indicator

Description

On

Both the power supply and the blower are operational.

Flashing

The power supply or the blower locate function is active.

Off

The power supply or the blower is non–operational. When

there is a blower problem, the other blower runs at a higher

speed. Recommended corrective actions:

Check blower for proper operation. Replace if defective.

Check power supplies for proper operation. Replace if

defective.

Drive enclosure EMU

The EMU provides increased protection against catastrophic failures. The EMU detects conditions such

as failed power supplies, failed blowers, elevated temperatures, and external air sense faults and

communicates these conditions to the storage system controllers.
The EMU for Fibre Channel-Arbitrated Loop (FC–AL) drive enclosures is fully compliant with SCSI-3

Enclosure Services (SES), and mounts in the left rear bay of a drive enclosure. See

Figure 10

.

Controls and displays

Figure 17

illustrates the location and function of the EMU displays, controls, and connectors.

Enterprise Virtual Array 3000/5000 user guide