Table 21 Fibre Channel switch basic troubleshooting

Problem

Recommended action

SFPs are installed in ports but no

indicators are lit.

1.

Verify that the power cord is firmly seated in the switch and is

connected to the power outlet.

2.

Check the power indicator to verify that the switch is on.

SFP is installed, but the Port Bypassed

indicator is lit.

Re-seat the SFP. If the same condition occurs, the SFP is probably

faulty and should be replaced.

SFP is installed, but the SFP status

indicator and the Port Bypassed indicator

are lit.

This condition indicates that the switch is not receiving a valid

Fibre Channel signal or that the switch is receiving an LIP.

1.

Ensure that the switch is powered on.

2.

Contact your HP authorized service representative for further

assistance.

SFP is installed and the SFP status

indicator is lit, but the devices are not

communicating.

This condition indicates that the switch is receiving a valid Fibre

Channel signal, but there are no upper level protocols active.

1.

Verify that you are running the correct firmware on all storage

system hardware.

2.

Check the Loop Operational indicator.

a.

If the Loop Operational indicator is lit, the devices have

completed initialization.

b.

If the Loop Operational indicator is off, the devices were

not initialized. Disconnect the devices from the switch.

Reconnect the devices one at a time. This allows you to

isolate the device that is responsible for the loop failure.

3.

Contact your authorized service representative for further

assistance.

HSV controllers

This section describes the major feature and functions of the HSV110 and HSV100 controllers. Each

Enterprise Virtual Array includes a pair of controllers.

Figure 22

shows the HSV controller.