Disk drive blank, Power supplies and blowers, 16 power supply and blower assembly components – HP 3000 Enterprise Virtual Array User Manual
Page 49: 10 operational disk drive status indications, 11 non-operational disk drive status indications, Table 10, Table 11
Table 10 Operational disk drive status indications
Activity
Online
Fault
Description
Flashing
On
Off
Initial startup.
On
On
Off
The drive is online but is not being accessed.
Flashing
Flashing
Flashing
The drive is being located.
Flashing
On
Off
The drive is operational and active.
Table 11 Non-operational disk drive status indications
Activity
Online
Fault
Description
On
On
On
Indicates no connection or the controllers are offline.
Recommended corrective actions:
1.
Check power supplies for proper operation.
2.
If defective, replace disk drive.
On
Off
Flashing
Indicates disk drive error/not active. Recommended
corrective actions:
1.
Verify FC loop continuity.
2.
Replace disk drive.
Disk drive blank
To maintain the proper enclosure air flow, a disk drive or a disk drive blank must be installed in each
drive bay. The disk drive blank maintains proper airflow within the disk enclosure.
Power supplies and blowers
This section describes the function and operation of the disk enclosure power supplies and blowers.
illustrates the major power supply and cooling components.
CXO7489A
1
3
4
5
5
6
2
Figure 16 Power supply and blower assembly components
1. Power supply
2. Status indicator
3. AC Input connector with bail
4. Module latch (wine-colored)
5. Blower tabs (wine-colored)
6. Blower
Enterprise Virtual Array 3000/5000 user guide