beautypg.com

HP XP20000XP24000 Disk Array User Manual

Page 207

background image

Troubleshooting

7-19

Hitachi USP V Cross-OS File Exchange User’s Guide

-240

Parameter: Direction, PAD, and DEL not

matched

The combination of otm direction,

PAD=Yes, and DEL=No is not allowed.

For FXotm with the padding function, make sure that the
delimiter option is specified as Yes (or set padding=No).

-241

Parameter: Direction and RDW not matched
The combination of otm data transfer

direction and RDW=Yes is not allowed.

When the FX data transfer direction is otm, make sure
that the RDW option is specified as No.

-242

Parameter: Code conv. and RDW not matched
The combination of RDW=Yes and code

conversion other than No is not allowed.

When the code conversion option is EA or File_name,
make sure that the RDW option is specified as No. When
RDW=Yes, the code conversion option must be specified
as No.

-243

Parameter: Padding and RDW not matched
The combination of RDW=Yes and

padding=Yes is not allowed.

When the padding option is specified as Yes, make sure
that the RDW option is specified as No.
When the RDW option is specified as Yes, make sure that
the padding option is specified as No.

-244

Parameter: Delimiter and RDW not matched
The combination of RDW=Yes and

delimiter=Yes is not allowed.

When the delimiter option is specified as Yes, make sure
that the RDW option is specified as No.
When the RDW option is specified as Yes, make sure that
the delimiter option is specified as No.

-245

Parameter : Specified VOLSER isn’t defined

Volume Definition file.

Specified VOLSER isn’t defined the volume

definition file.

Check whether specified VOLSER is defined in the volume
definition file.

-300

Parameter definition file : Length error
The record length in the parameter definition

file is too long.

Specify the record length less than 3200 characters (do
not include delimiter).

-301

Mainframe file name : Length error
An input dataset name(in case of FXmto) or

an output dataset name(in case of FXotm)
in the parameter definition file is too long.

Specify an input/output dataset name less than 1025
characters.

-302

Opensystem file name : Length error
An input filet name(in case of FXotm) or an

output file name(in case of FXmto) in the
parameter definition file is too long.

Specify an input/output file name less than 1025
characters.

-303

Code conversion Length error
A code conversion file name in the

parameter definition file is too long.

Specify a code conversion file name less than 1025
characters.

-304

VSE: Length error
A VSE parameter in the parameter definition

file is not corrected.

Specify a VSE parameter less than 21 characters.

-305

VSE record-format: Length error

The record format for VSE in the parameter

definition file is not corrected.

Specify the record format for VSE less than 3 characters.

-306

VSE record-length: Length error
The record length for VSE in the parameter

definition file is not corrected.

Specify the record length for VSE less than 6 characters.