HP XP20000XP24000 Disk Array User Manual
Page 207
Troubleshooting
7-19
Hitachi USP V Cross-OS File Exchange User’s Guide
-240
Parameter: Direction, PAD, and DEL not
matched
The combination of otm direction,
PAD=Yes, and DEL=No is not allowed.
For FXotm with the padding function, make sure that the
delimiter option is specified as Yes (or set padding=No).
-241
Parameter: Direction and RDW not matched
The combination of otm data transfer
direction and RDW=Yes is not allowed.
When the FX data transfer direction is otm, make sure
that the RDW option is specified as No.
-242
Parameter: Code conv. and RDW not matched
The combination of RDW=Yes and code
conversion other than No is not allowed.
When the code conversion option is EA or File_name,
make sure that the RDW option is specified as No. When
RDW=Yes, the code conversion option must be specified
as No.
-243
Parameter: Padding and RDW not matched
The combination of RDW=Yes and
padding=Yes is not allowed.
When the padding option is specified as Yes, make sure
that the RDW option is specified as No.
When the RDW option is specified as Yes, make sure that
the padding option is specified as No.
-244
Parameter: Delimiter and RDW not matched
The combination of RDW=Yes and
delimiter=Yes is not allowed.
When the delimiter option is specified as Yes, make sure
that the RDW option is specified as No.
When the RDW option is specified as Yes, make sure that
the delimiter option is specified as No.
-245
Parameter : Specified VOLSER isn’t defined
Volume Definition file.
Specified VOLSER isn’t defined the volume
definition file.
Check whether specified VOLSER is defined in the volume
definition file.
-300
Parameter definition file : Length error
The record length in the parameter definition
file is too long.
Specify the record length less than 3200 characters (do
not include delimiter).
-301
Mainframe file name : Length error
An input dataset name(in case of FXmto) or
an output dataset name(in case of FXotm)
in the parameter definition file is too long.
Specify an input/output dataset name less than 1025
characters.
-302
Opensystem file name : Length error
An input filet name(in case of FXotm) or an
output file name(in case of FXmto) in the
parameter definition file is too long.
Specify an input/output file name less than 1025
characters.
-303
Code conversion Length error
A code conversion file name in the
parameter definition file is too long.
Specify a code conversion file name less than 1025
characters.
-304
VSE: Length error
A VSE parameter in the parameter definition
file is not corrected.
Specify a VSE parameter less than 21 characters.
-305
VSE record-format: Length error
The record format for VSE in the parameter
definition file is not corrected.
Specify the record format for VSE less than 3 characters.
-306
VSE record-length: Length error
The record length for VSE in the parameter
definition file is not corrected.
Specify the record length for VSE less than 6 characters.