HP XP20000XP24000 Disk Array User Manual
Page 119
Using the Cross-Os File Exchange Software
4-25
Hitachi USP V Cross-OS File Exchange User’s Guide
Figure 4-18
FMT Utility for Windows 2000/2003/Windows NT
3. On the Format panel, enter the six-character volume serial number for the
OPEN-x volume being formatted in the VOLSER field. Make sure to use the
same volser for this volume in the FXoto volume definition file.
4. Specify the physical drive number (device number) for the OPEN-x volume
being formatted in the Physical drive No field. Make sure to use the same
physical drive number for this volume in the FXoto volume definition file.
5. Specify the number of cylinders for the OPEN-x volume in the Cylinder Size
field. The Min. button enters 2 (two) cylinders, and the Max. button enters
5818 cylinders. If the OPEN-x volume is standard size (e.g., OPEN-3), use the
maximum size of 5818 cylinders. If the OPEN-x volume is custom size (e.g.,
OPEN-3*n VIR device), use the following value: (# of cylinders defined for
VIR) − 7. For example, if the VIR OPEN-x volume is defined with 1000
cylinders, enter 993 in the Cylinder Size field.
Note: The maximum size for the Allocater is 4369 cylinders.
6. When the VSN, physical drive number, and cylinder size are correct, select
the Start button. When the Format confirmation appears (see Figure 3-2),
select OK to perform the requested FMT format operation, or select Cancel
to cancel your request.
Figure 4-19
FMT Format Warning and Confirmation