4. Enter the desired FCU initiation parameters for the first FX operation.
–
Use the
buttons to select the transfer direction (M to O or O to
M).
–
Enter the source and target datasets/files in the Mainframe File field
(VSN:dataset), and/or Open-system file field (/directory/…/filename).
–
Open the Option panel using the View-Option… menu command (
),
and then select the desired FCU options (code conversion, padding,
delimiters, etc.). Do not select Continuous execution or Clear log file
when creating a new FCU parameter definition file. Close the Option panel
when you are done.
5. When the FCU initiation parameters are correct, select the Parameter-Save-
Insert command (
) to save the current parameter set in the new FCU
parameter definition file. The status bar now displays 1/1 to indicate that line
one of one is now being displayed. If the FX volume is available, you can
perform the operation now by clicking Execute. If the Execute button is not
enabled, the parameter set has not been saved in the file.
6. Repeat steps (4) and (5) to add each new FCU initiation parameter set to the
new FCU parameter definition file. If desired, you can use the Parameter-
Wipe menu command ( ) to clear the screen before you enter the next set
of parameters, or you can leave the parameters and make changes where
needed to specify the next new line in the file. Make sure to keep FX
operations which use OPEN-x FMT volumes in a separate FCU parameter
definition file from operations which use -A, -B, and -C volumes.
7. If you need to insert a new line between two existing lines, go to the line
above/before the line to be inserted using the Parameter-Load commands
(
), change the parameters as needed, and then use the
Parameter-Save-Insert command (
) to insert the new line. The new line
is inserted below/after the current line number.
8. If you need to modify an existing line, go to the line to be modified using the
Parameter-Load commands, change the parameters as needed, and then
use the Parameter-Save-Replace command (
) to modify the line as
specified.
9. When you want to save your new FCU parameter definition file, select the
File-Save menu command (
). The file extension must be .prm.