7-12 Troubleshooting
Hitachi USP V Cross-OS File Exchange User’s Guide
Error
Code
Error Message and Description
Recommended Action(s)
-206
RDW error: PADDING not supported
Padding is not specified as No
when RDW=Yes.
Padding cannot be processed when RDW=Yes. Change the
padding parameter to No.
-207
RDW error: DELIMITER not
supported
Delimiter is not specified as No
when RDW=Yes.
Delimiters cannot be processed when RDW=Yes. Change
the delimiter parameter to No.
-210
Parameter file: Comment line
This is a comment line in the
parameter file.
If you specify Load, FCU will move to the next line. You can
also replace the comment line with a valid parameter.
-220
Parameter: VSE select error
The VSE parameter format is not
correct.
Make sure that the number of VSE parameters is correct and
that a comma is used correctly to separate the VSE
parameters.
-221
Parameter: VSE record format error
Record format in the VSE
parameter is not correct.
Make sure that the record format is set to either one of
F/FB/V/VB.
-222
Parameter: VSE record length error
Record length in the VSE
parameter is not correct.
Make sure that the record length is set to the correct value
within the extent allowed.
-223
Parameter: VSE block length error
Block length in the VSE
parameter is not correct.
Make sure that the block length is set to the correct value
within the extent allowed.
-230
No code conv. table file: No code
conv. table
The code conversion table was
not found.
Make sure that the code conversion table file name is correct
and that the file exists. This error may also be reported if you
mix mainframe and OPEN-x devices in the same FX volume
definition file.
-231
Code conv. table: Open error
The code conversion table could
not be opened.
Refer to the OS user manuals for assistance.
-233
Code conv. table: Close error
The code conversion table could
not be closed.
Refer to the OS user manuals for assistance.
-234
Code conv. table: Get file data error
The size of the code conversion
table could not be obtained.
Check the contents of the file. Refer to the OS user manuals
for assistance.
-235
Code conv. table: File size error
The size of the code conv table is
not correct.
Make sure that the size of the code conversion table is 256
bytes.
-236
Code conv. table function: Invalid
argument
No source data to be converted
was found.
Check the contents of the input file, especially the delimiters.
-238
Code conv. table name: No data
The file name of the code
conversion table is not specified.
If you do not specify EA or No for the code conversion
option, make sure to specify the correct file name of your