IBM V7000 series

System parameters for connecting IBM V7000 series

When you connect an IBM V7000 series as an external storage system, set the system parameters
of the IBM V7000 series according to the following table. For the system parameters that are not
in the following table, see the documentation of the IBM V7000 series and set the parameters
appropriately for the connecting configuration.

Table 31 System parameters for connecting IBM V7000 series

Parameter setting

Parameter

Generic

host type

Notes on connecting IBM V7000 series

The model name of the IBM V7000 series is displayed as "SVC" on the Remote Web Console
window.

Notes on connecting IBM XIV series

When connecting an IBM XIV series as an external storage system, note that the type of display
of the system and device serial number differs between IBM XIV series and P9500.

Table 32 Serial number display (IBM XIV series)

Display in IBM XIV

Display in P9500

Type

Item

Type

Item

Decimal value

The first 2 digits of (System) Serial
number

Decimal value

The first 2 digits of Serial Number

Decimal value

The last 5 digits of (System) Serial
number

Hexadecimal value

The last 5 digits of Serial Number

Decimal value

Device serial number

Hexadecimal value

Characteristic 1

Fujitsu FibreCAT CX series

System parameters for connecting Fujitsu FibreCAT CX series

When you connect an Fujitsu FibreCAT CX series as an external storage system, set the system
parameters of the Fujitsu FibreCAT CX series according to the following table. For the system
parameters that are not in the following table, see the documentation of the Fujitsu FibreCAT CX
series and set the parameters appropriately for the connecting configuration.

Table 33 System parameters for connecting Fujitsu FibreCAT CX series

Parameter setting

Parameter

CLARiiON Open

Initiator Type

2

Failover Mode

Connecting Fujitsu FibreCAT CX series

Volumes created with the RAID0 level or Individual Disk Units (JBOD disks) of Fujitsu FibreCAT CX
series are not supported.

System parameters for connecting SGI IS4600 series

When you connect an SGI IS4600 series as an external storage system, set the system parameters
of the SGI IS4600 series according to the following table. For system parameters not listed in this

82