EMC CLARiiON CX series
When you connect an EMC CLARiiON CX series as an external storage system, set the system
parameters of the EMC CLARiiON CX series according to the following table. For system parameters
not in the following table, see the EMC CLARiiON CX series documentation and set the parameters
appropriately for the connecting configuration.
Table 27 System parameters (EMC CLARiiON CX series)
Parameter setting
Parameter
CLARiiON Open
Initiator Type
2
Failover Mode
Notes on connecting EMC CLARiiON CX series
Volumes created with Individual Disk Units (JBOD disks) of EMC CLARiiON CX series are not
supported.
EMC Symmetrix series
System parameters for connecting EMC Symmetrix series
When you connect an EMC Symmetrix series as an external storage system, set the system
parameters of the EMC Symmetrix series according to the following table. For the system parameters
that are not in the following table, see the documentation of the EMC Symmetrix series and set the
parameters appropriately for the connecting configuration.
Table 28 System parameters for connecting EMC Symmetrix series
Parameter setting
Parameter
Enable
SC3 flag
Disable
SPC2 flag
IBM DS3000/DS4000/DS5000 series
When connecting an IBM DS3000/DS4000/DS5000 series as an external storage system, set
the system parameters of the IBM DS3000/DS4000/DS5000 series according to the following
table. For the system parameters that are not in the following table, see the documentation of the
IBM DS3000/DS4000/DS5000 series and set the parameters appropriately for the connecting
configuration.
Table 29 System parameter (IBM DS3000/DS4000/DS5000 series)
Parameter setting
Parameter
When alternate paths are connected to different clusters on the
DS3000/DS4000/DS5000 series side: Linux
host type
System parameters for connecting IBM SVC series
When connecting an IBM SVC series as an external storage system, set the system parameters of
the IBM SVC series according to the following table. For the system parameters that are not in the
following table, see the documentation of the IBM SVC series and set the parameters appropriately
for the connecting configuration.
Table 30 System parameters (IBM SVC series)
Parameter setting
Parameter
Generic
host type
EMC CLARiiON CX series