Vc domain status change notifications, Snmp settings (snmp enet settings) – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 43
Domain management 43
•
connUnitPortStatusChange (1.3.6.1.3.94.0.6)
INFO—The overall status of the connectivity unit has changed. Sent whenever any of the following
notifications occur:
o
UserPort.StateChange
o
UserPort.OperChange
•
coldStart
CRITICAL—A coldStart trap signifies that the SNMP agent is reinitializing itself and that its
configuration might have been altered.
•
authenticationFailure
CRITICAL—An authenticationFailure trap signifies that the SNMP agent has received a protocol
message that is not properly authenticated.
VC domain status change notifications
When a VC domain changes status, VC Manager generates a trap. The state changes are:
•
NORMAL—The component is fully functional.
•
CRITICAL—The component is incapable of managing installed VC components.
•
MAJOR—One or more of the component's subsystems are not operating properly, causing serious
disruption to functions.
•
MINOR—One or more of a component's subsystems are not operating properly, causing slight
disruption to functions.
•
WARNING—The component has a potential problem.
•
UNKNOWN—VC Manager has not yet established communication with the component.
SNMP Settings (SNMP Enet Settings)
By enabling SNMP for VC-Enet modules, network management systems can monitor VC-Enet modules in
the domain for events such as warnings and errors that might require corrective actions. The user must
have network administrator privileges to administer SNMP Enet settings.
- 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem