Choosing a raid level, 7 summary of raid methods, 8 choosing a raid level – HP StorageWorks 1510i Modular Smart Array User Manual
Page 90
Table 7 Summary of RAID methods
RAID 0
RAID 1+0
RAID 5
RAID 6
Alternative name
Striping
Mirroring
Distributed Data
Guarding (DDG)
Advanced Data
Guarding (ADG)
Usable drive
space*
100%
50%
67% to 93%
50% to 96%
Usable drive space
formula
n
n/2
(n-1)/n
(n-2)/n
Minimum number
of physical drives
1
2
3
4
Tolerates physical
drive failure?
No
Yes
Yes
Yes
Tolerates
simultaneous failure
of more than one
physical drive?
No
Only if no two
failed drives are in
a mirrored pair
No
Yes
Read performance
High
High
High
High
Write performance
High
Medium
Low
Low
Relative cost
Low
High
Medium
Medium
*Values for usable drive space are calculated with these assumptions:
•
All physical drives in the array have the same capacity.
•
Online spares are not used.
•
No more than 14 physical drives are used per array for RAID 5.
•
No more than 56 drives are used with RAID 6.
Choosing a RAID level
Use
to help you determine the best RAID level for your environment.
Table 8 Choosing a RAID level
Most important characteristic
Also important
Suggested RAID level
Fault tolerance
Cost effectiveness
RAID 6
I/O performance
RAID 1+0
Cost effectiveness
Fault tolerance
RAID 6*
I/O performance
RAID 5 (RAID 0 if fault tolerance
is not required)
I/O performance
Cost effectiveness
RAID 5 (RAID 0 if fault tolerance
is not required)
Fault tolerance
RAID 1+0
90