Security tasks, Setting up access control lists, 13 sample configuration—after adding initiators – HP StorageWorks 1510i Modular Smart Array User Manual
Page 51
Figure 13 Sample configuration—after adding initiators
IMPORTANT:
Perform the following tasks to complete the configuration:
•
Enter security settings (optional, but recommended). (For more information, see
•
Enter configuration settings in the iSCSI initiator configuration software utility (on the server),
including:
• Adding target portals for the initiator to access.
• Configuring the target portals. (Be sure to select the option to automatically restore the connection
each time the system restarts.)
• Logging on to establish an active session.
Security tasks
Security can include one or all of the following:
• Setting up Access Control Lists
• Setting up CHAP authentication
• Setting the SSL certificate
Setting up Access Control Lists
Access control lists (ACLs) provide security at the LUN level. In an ACL, you indicate the initiator(s) that
can access specific mapped logical drive units of a target.
NOTE:
Repeat all steps in this section for each target for which you want to establish an ACL.
1.
From the server, open the iSCSI initiator software and close any active connections to the target. This
ensures that there is no I/O activity on the target.
HP Storage Management Utility user guide
51