Mapping logical drives to the target

1.

Select Target > Map Logical Drive to Target.

2.

Enter the requested information for the mapped logical drive.

NOTE:

• The utility suggests a default value for the Mapped LUN Alias. Accept the default or

enter a user-defined, content-descriptive value.

• The utility suggests a default number to assign to the mapping, beginning with number

1. Accept the default or expand the drop-down box to select a different number. HP

recommends accepting the default. The Mapped LUN number is the name presented

to the initiator.

• All available, unmapped logical drives are included in the selection list.
• One logical drive at a time can be mapped to a target. To map additional logical

drives to this target, repeat these steps.

3.

When the display refreshes, verify that the mapped logical drive is shown in the component list.

4.

To map additional logical drives to this same target, repeat

Step 1

through

Step 3

in this section.

Configuring the redundant controller for a target (dual-controller configurations only)

IMPORTANT:

Dual-controller configurations must create an additional portal group for each target, using portals on

the redundant Ethernet iSCSI module to establish a redundant path. Redundant data ports include SB0,

and SB1. For targets assigned to logical port SA0, use logical port SB0 as the redundant path. For

targets assigned to logical port SA1, use logical port SB1 as the redundant path.

The following steps are a summary of the steps included in

Creating target portal groups

and

Assigning

portals to the portal group

, but are for establishing a redundant path:

1.

Create a portal group by selecting Target > Create Portal Group. Assign a name to the redundant

portal group.

HP Storage Management Utility user guide