beautypg.com

Configuring data ports – HP StorageWorks 1510i Modular Smart Array User Manual

Page 35

background image

5.

Enter the settings for the management port.

NOTE:

• Port State must be

Enabled

(default) to use the SMU. If the management port state was

disabled, you must use the Command Line Interface (CLI) to re-enable it. (For more

information, see the Command Line Interface user guide.)

• Assign a Host Name to the storage system (default: chassis serial number). HP

recommends changing this to a more helpful user-defined value.

• Port Name MA0 is the default management port. Although other ports can be

configured as the primary management port, HP recommends configuring and using

the default.

• To control the path of management traffic to and from the array controller and to

add one level of system security, HP recommends assigning a static IP address to the

management port that is in a different LAN segment than the data ports. To assign

a static IP address, expand the DHCP Setting drop-down box and change the setting

to Disabled. The page expands (shown), showing the currently assigned IP address.

Change this to the address you want to use for management traffic. After changing the

IP address, you may need to re-connect to the SMU using the newly assigned IP address.

• By default, VLAN ID is 0, meaning that traffic flowing from the port to the switch will be

untagged. To assign a VLAN for this port to use, enter its value. VLANs are set up on

the switch, and are used as one method of controlling access to the storage system.

IMPORTANT:

For dual-controller configurations, repeat these steps to configure the management port on the other

controller.

The default management port for controller A is MA0.

The default management port for controller B is MB0.

Configuring data ports

Configuring each data port includes two steps:

Assigning one or more IP addresses to the port (

Step 1

).

Assigning one or more TCP portals to each IP address (

Step 4

).

IMPORTANT:

Configure all data ports you plan to use, including ports on the Ethernet iSCSI module associated

with the controller in slot 2, if installed.

HP Storage Management Utility user guide

35