beautypg.com

Setting up mutual chap authentication, Step 1, Step 4 – HP StorageWorks 1510i Modular Smart Array User Manual

Page 55

background image

1.

In the SMU, select Target > CHAP Settings.

2.

Expand the CHAP State drop-down box and change the setting to Enabled.

NOTE:

If CHAP settings have already been entered for this target, the display is contracted and

protected by a gateway check box. To change existing CHAP settings, clear the Use

Existing CHAP Settings check box. The page expands, allowing access to the settings.

3.

Enter the CHAP Secret.

4.

On the server, open the iSCSI initiator software utility. Navigate through the iSCSI utility and enter

the same CHAP secret assigned in the SMU.

Setting up mutual CHAP authentication

Setting up mutual CHAP authentication between an initiator and a target requires:

Entering a target-specific CHAP secret in both the SMU and the iSCSI initiator software utility.

Entering an initiator-specific CHAP secret in both the SMU and the iSCSI initiator software utility.

Enabling mutual authentication in the iSCSI initiator software utility.

1.

To enter a target-specific CHAP secret in both the SMU and the iSCSI initiator software utility, see

Setting up target-specific initiator-to-target CHAP authentication

” on page 54.

HP Storage Management Utility user guide

55