Disabling data ports (enable/disable port), Disabling a controller (disable controller), Disabling auto-path switching (redundancy – HP StorageWorks 1510i Modular Smart Array User Manual

Page 64: Settings)

background image

NOTE:

Some of the components that can not be deleted while in use include:

Removing a portal from a portal group

Deleting a portal group

Deleting a target

Disabling automatic path switching (Redundancy Settings)

NOTE:

This task is available for dual-controller configurations only.

1.

Select Storage System > Redundancy Settings.

2.

Expand the Preferred Path Mode drop-down box and select one of the following options:
• Automatic (default)—Based on I/O load, the system automatically determines and assigns the

optimal path (controller ownership) for each LUNs. If a path is manually specified for a LUN with

the Set Preferred Path task, it may subsequently be re-assigned by the system.

• Manual—The path for each LUN must be set manually with the Set Preferred Path task.

Disabling data ports (Enable/Disable Port)

By default, all ports on the Ethernet iSCSI module are enabled.
To disable or re-enable a port, select the port in the component list, and then select Enable/Disable Port.

Disabling a controller (Disable Controller)

When removing a controller for service, HP recommends first disabling the controller.
To disable a controller, select the controller from the component list, and then select Disable Controller.

64