Set snmp contact, Set snmp location, Set snmp trapdest – HP ProLiant SL2500 Scalable System User Manual
Page 91
CLI commands 91
Set SNMP contact
•
Command:
SET SNMP CONTACT "
•
Description:
Sets the MIB II sysContact field.
Set SNMP location
•
Command:
SET SNMP LOCATION "
•
Description:
Sets the MIB II sysLocation field.
Set SNMP trapdest
•
Command:
SET SNMP TRAPDEST <
•
Description:
o
Sets the IP addresses where SNMP traps are sent.
You can set up to four SNMP trap destinations. For example, enter:
SET SNMP TRAPDEST x.x.x.x y.y.y.y z.z.z.z a.a.a.a
If you specify NONE, then no trap destinations are set. For example, enter:
SET SNMP TRAPDEST NONE
o
HP APM supports the following SNMP traps:
NOTE:
SNMP traps denoted by an * are not supported on the HP ProLiant s6500 Chassis.
—
cpqRackNameChanged
—
cpqRackEnclosureRemoved
—
cpqRackEnclosureInserted
—
cpqRackEnclosureFanRemoved *
—
cpqRackEnclosureFanInserted *
—
cpqRackEnclosureFanFailed
—
cpqRackEnclosureFanOK
—
cpqRackPowerSupplyFailed
—
cpqRackPowerSupplyOK
—
cpqRackPowerSupplyRemoved
—
cpqRackPowerSupplyInserted
—
cpqRackServerBladeRemoved