Showing assetinfo – HP ProLiant SL2500 Scalable System User Manual
Page 29
Command Line Interface 29
Showing assetinfo
To list all the chassis in the rack in a report format, enter SHOW ASSETINFO.
For example, the following text might appear:
slapm> show assetinfo 1 7
1: Dist. Module
7: SL enclosure
Product Name :HP ProLiant s6500
Product SKU :629235-B21
Serial Number:USE119A2MM
UID :off
Status :
1 : Compute node (active) Asset tag: myserver1
Serial #: USE119A2YW
2 : Compute node (active) Asset tag: myserver2
Serial #: USE119A2YT
3 : Compute node (active) Asset tag: myserver3
Serial #: USE119A319
4 : Compute node (active) Asset tag: myserver4
Serial #: USE119A31C
5 : Compute node (active) Asset tag: myserver5
Serial #: USE119A2N8
6 : Compute node (active) Asset tag: myserver6
Serial #: USE119A2N3
7 : Compute node (active) Asset tag: myserver7
Serial #: USE119A2N4
8 : Compute node (active) Asset tag: myserver8
Serial #: USE121AJYH
Power supply slot 1 is occupied, status good
Power supply slot 2 is occupied, status good
Power supply slot 3 is occupied, status good
Power supply slot 4 is occupied, status good
Fan slot 1 status good
Fan slot 2 status good
Fan slot 3 status good
Fan slot 4 status good
Fan slot 5 status good
Fan slot 6 status good
Fan slot 7 status good
Fan slot 8 status good
This command also requests and shows any asset tags from the chassis and any 30- or 60-amp PDUs that are
in the rack.
The asset tag information for 30- or 60-amp PDUs can be set through the SET ASSETINFO command.
For example, the following text might appear:
> show assetinfo pdm2
10: [PDM2] HP 60A PDU
Model : STI Serial TrueRMS PDU
Serial Number: ADFV0000083
Asset Tag : SCI Lab PDU
Part Number : QL192A
Firmware Rev : 1.0a
Switched Outlets:
1: enabled