Troubleshooting, Alert messages, Devices not discovered – HP ProLiant SL2500 Scalable System User Manual
Page 74
![background image](/manuals/397602/74/background.png)
Troubleshooting 74
Troubleshooting
Alert messages
The following messages appear in HP APM.
Message
Where this issue occurs
Required action
There was an error
transferring the file,
image upgrade not
performed.
Firmware upgrade
Verify network connectivity, and then retry the
firmware upgrade.
Error upgrading
firmware image.
Firmware upgrade
Message appears with other logs describing the
actual issue. Review logs to identify, and then
resolve issue.
Dist. Module on Power
Manager Chassis port
<#> has excessive
errors and has been
marked as failed.
All modes of operation
Verify HP APM and HP APM Distribution
Module cabling.
Power Manager Chassis
port <#> on Dist.
Module <#> has
excessive errors and
has been marked as
failed.
All modes of operation
Verify HP APM and HP APM Distribution
Module cabling.
Power Manager Chassis
rendered non
functional, redundant
Power Manager Chassis
is not supported by
this firmware version.
Redundant HP APM inserted
into HP APM enclosure
Remove both HP APM controllers, and then
reinsert only one controller.
The SL enclosure on
Power Manager port
<#>, Dist. Module port
<#> does not support
the Power Manager.
SL Power Management
Controller at the named
location does not support HP
APM.
Update the SL Power Management Controller in
that chassis. If no update is available, the SL
Power Management Controller does not offer
support for HP APM.
For messages not listed, contact HP Support
"Support and other resources (on page
)."
Devices not discovered
If devices are not discovered, perform the following steps:
1.
Check the link and power LEDs.
2.
Check the cables.
3.
Reboot HP APM.