Showing and clearing the fault log, External logging, Hp apm fault messages – HP ProLiant SL2500 Scalable System User Manual
Page 35
Logging 35
Showing and clearing the fault log
To show the fault log, enter SHOW FAULTS.
As an example, the following text might appear on screen:
> show faults
May 4 19:43:43 APM-D4C9EFCB01CA system.0: Power Manager Power Supply 1 is
non operational
May 5 01:42:20 APM-D4C9EFCB01CA system.0: Timeout waiting for Dist. Module
mutex on Power Manager port 3
May 6 03:51:16 APM-D4C9EFCB01CA system: Failed login attempt with user
'Administrator' from 192.168.1.1
To clear the fault log, enter CLEAR FAULTS.
External logging
To show the syslog server address configuration information, enter SHOW SYSLOG.
To set the syslog server address configuration, enter SET SYSLOG x.x.x.x.
Using an existing syslog server provides:
•
Redundant copy of events and logs
•
No limits to number of events that can be logged
HP APM fault messages
Fault logged message
Description
There was an error transferring the file,
image upgrade not performed
Error occurred during firmware upgrade.
Error upgrading firmware image
Firmware image not upgraded due to an error.
Distribution Module on Power Manager
port X has excessive errors and has been
marked as failed
RS-485 port is having excessive errors and has failed.
Distribution Module port X on Power
Manager port Y has excessive errors and
has been marked as failed
RS-485 port is having excessive errors and has failed.
Transmit failed to write
Hardware error transmitting a packet.
Read error on UART
Hardware error receiving a packet.
Power Manager Power supply 1 is non
operational
Power supply in slot 1 is not supplying power to the HP APM chassis.
There is a 20 second delay in detecting a power supply status
change.
Power Manager Power supply 2 is non
operational
Power supply in slot 2 is not supplying power to the HP APM chassis.
Firmware update to Distribution Module,
port X failed, retry Y being attempted
While upgrading the firmware on a Power Manager Distribution
Module, an error occurred. Retry being attempted.
Firmware update to Distribution Module,
port X - all retries, failed, giving up
While upgrading the firmware on a Power Manager Distribution
Module, too many errors occurred and the operation has been
terminated.