Chapter 3

Installing Mass Storage Devices

20

If the round hole does not align with the mounting hole on the drive,
use the nearest elongated hole.

c. Repeat steps a-b on the other side of the cage. See Figures 3-2 and 3-3.

1st

2nd

3rd

4th

HDD4 (Shelf 7)

HDD3 (Shelf 6)

Tab

Tab

Figure 3-3. Hard Disk Drive Cage Screw Holes

11. Reinstall the hard disk drive cage.

Ensure the tabs at the front on the cage slide into the slots provided for
each one. See Figures 3-2 and 3-3.

12. Connect the SCSI cable to the disk drive(s). See Figure 3-1.

There are five connectors on the standard SCSI cable, with four of the
connectors intended for the four hard disk drives in the hard disk drive
cage. The extra connector may be used for the optional tape drive. The
standard SCSI cable has a terminator at the end of the cable.

NOTE

The slower speed of the tape drive may slow disk access time
for the Ultra-2 SCSI drives. You may connect the tape drive
separately from the Ultra-2 SCSI drives using the optional
internal accessory SCSI cable. See Figure 3-6.

13. Connect the power cable to the drives.