HP H-series Enterprise Fabric Management Suite Software User Manual
Page 87
HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Enterprise Fabric Management Suite User Guide
87
Services Group
NTP Client Enabled
Enables switches to synchronize their time to a centralized server.
Enabled or Disabled.
NTP Server Address
IP address of the centralized NTP server. Ethernet connection to NTP
server is required.
FDMI Enable
Fabric Device Management Interface status. If enabled, device
information can be obtained, managed, and saved through the fabric
using Name Service Management Server functions. If FDMI is
Enabled on the entry switch, Enterprise Fabric Management Suite
reports all FDMI information reported by the entry switch.
FDMI HBA Entry Limit
Maximum number of HBAs that can be registered with a switch
Embedded GUI Enabled
Web applet status. Indicates whether the web applet on the switch is
Enabled or Disabled.
Inactivity Timeout
Number of minutes the switch waits before terminating an idle
command line interface (CLI) session. Zero (0) disables the timeout
threshold.
GUI Mgmt Enabled
Web applet status. If this option is disabled, the switch cannot be
managed using the web applet.
Telnet Enabled
Telnet client status Enabled or Disabled
SSH Enabled
Secure Shell status. If Enabled, an encrypted data path is provided
for command line interface sessions.
SSL Enabled
Secure Sockets Layer status. If enabled, encryption for switch
management web applet and CIM sessions is provided.
CIM Enabled
Common Interface Model status. The CIM agent is based on the
Storage Networking Industry Association (SNIA) Storage
Management Initiative Specification (SMI-S), which is the standard for
SAN management in a heterogeneous environment.
FTP Enabled
FTP status Enabled or Disabled
Management Server Enabled
Management server status Enabled or Disabled
SNMP Enabled
SNMP status, Enabled or Disabled
Call Home Enabled
Call Home status. If enabled and configured, switches can send alerts
to pagers and email. Users can configure the type of events and
where the alerts are sent.
Zones/Security Group
Interop Mode
Standard
Legacy Address Format
None
Merge Auto Save
If enabled, any zoning updates from the fabric are saved in
permanent (non-volatile) memory as well as temporary memory. if
disabled, any zoning updates from the fabric are saved only in
temporary memory and are lost after a switch reset.
Default Zone
Enables or disables communication between ports and devices not
defined in the active zone set, or when there is no active zone set
Table 11
Switch data window fields (continued)
Field
Description