HP H-series Enterprise Fabric Management Suite Software User Manual
Page 85
HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Enterprise Fabric Management Suite User Guide
85
First Port Address
Switch Fibre Channel address
World Wide Name
Switch World Wide Name
Serial Number
Number assigned to each chassis
Reason for Status
Reason for the operational state
Vendor
Switch manufacturer
MAC Address
Media Access Control address
Negotiated Domain ID
Domain ID currently being used by the fabric
Configured Domain ID
Domain ID, defined by network administrator
Domain ID Lock
Domain ID lock status. Prevents (True) or permits (False) dynamic
domain ID reassignment.
Number of Ports
Number of physical ports on the switch
Operational State
Switch operational state: Online, Offline, Diagnostic, Down
Administrative State
Current switch administrative state
Configured Admin State
Administrative state that is stored in the switch configuration
Beacon Status
Switch LEDs are blinking (On) or not blinking (Off).
Status Group
Operational State
Switch operational state: Online, Offline, Diagnostic, Down
Administrative State
Current switch administrative state
Configured Admin State
Administrative state that is stored in the switch configuration
Beacon Status
Beacon status. Switch LEDs are blinking (On) or not blinking (Off).
Reason for Status
Reason for the operational state
Temperature
Internal switch temperature °C
Fan 1 Status
Fan 1 operational status (dual power supply model only)
Fan 2 Status
Fan 2 operational status (dual power supply model only)
Fan 3 Status
Not applicable
Power Supply 1 Status
Power supply 1 operational status
Power Supply 2 Status
Power supply 2 operational status (dual power supply model only)
Temperature Failure Port
Shutdown
Non-configurable (always enabled for this switch). All ports are shut
down when the switch temperature exceeds the Failure Temperature.
Warning Temperature
Non-configurable temperature threshold, above which a warning
condition alarm is generated
Failure Temperature
Non-configurable temperature threshold, above which a failure
condition alarm is generated
POST Status
Current diagnostic state of the switch
POST Fault Code
Code value for the last recorded diagnostic test result recorded on the
switch
Test Status
Current diagnostic test status of switch
Table 11
Switch data window fields (continued)
Field
Description