Table 10 port/device icons, Configuring the zoning database, Figure 29 zoning config dialog box – HP H-series Enterprise Fabric Management Suite Software User Manual
Page 54: Merge auto save, 29 zoning config dialog box, 10 port/device icons, Configuring the, Zoning database
54
Managing Fabric Zoning
Configuring the zoning database
Use the Zoning Config dialog box (
) to change the Merge Auto Save, Default Zone, and Discard
Inactive configuration parameters. To open the Zoning Config dialog box, select Zoning > Edit Zoning
Config. After making the changes, click OK to put the new values into effect.
Figure 29
Zoning Config dialog box
Merge Auto Save
The Merge Auto Save parameter determines whether changes to the active zone set that a switch receives
from other switches in the fabric are saved to the zoning database on that switch. Changes are saved
when an updated zone set is activated. Zoning changes are always saved to temporary memory.
•
If Merge Auto Save is enabled, the switch firmware saves changes to the active zone set in temporary
memory and to the zoning database.
•
If Merge Auto Save is disabled, changes to the active zone set are stored only in temporary memory,
which is cleared when the switch is reset.
NOTE:
Disabling the Merge Auto Save parameter can be useful to prevent the propagation of zoning
information when experimenting with different zoning schemes. However, leaving the Merge Auto Save
parameter disabled can disrupt device configurations should a switch have to be reset. For this reason, the
Merge Auto Save parameter should be enabled in a production environment.
Table 10
Port/device icons
Icon
Description
Switch port icon—When not logged in
Switch port icon—When logged in
NL_Port (loop) device icon—When logged in to fabric
NL_Port (loop) device icon—When not logged in to fabric
N_Port device icon—When logged in to fabric
N_Port device icon—When not logged in to fabric