Message ID

Message Text

Explanation

KAPL05014-I The device object (aa...aa) was

registered as the path (bb...bb).

Details

The path (bb...bb: Core

logic path identifier) of the

device object (aa...aa:

Filter driver management

table address) was

successfully registered into

the core logic.

Action

None.

KAPL05018-

W

The FO processing in the path (aa)

failed. (bb:cc) Check the connection

status of the path %x. If there is no

problem with the connection status,

execute the DLMgetras utility to collect

error information, and then contact your

vendor or maintenance company. Refer

to the HDLM User's Guide for instructions

how to execute the DLMgetras utility.

Details

FO processing failed in the

path (aa...aa: Identifier of

the core logic path where

FO processing failed

(hexadecimal number)).
bb...bb: Error code

(hexadecimal number)
cc...cc: Fixed at 0

Action

The I/O being processed is

discarded. Check the

status of the device path

and take an appropriate

action. If there is no

problem with the

connection status of the

path, execute the

DLMgetras utility for

collecting error

information, and then

contact the HDLM vendor

or the maintenance

company if you have a

maintenance contract for

HDLM

KAPL05021-I Processing of IOCTL (aa...aa) completed

normally.

Details

The processing for the

requested IOCTL operation

was successful.
aa...aa: IOCTL code

(hexadecimal number)

Action

None.

KAPL05023-

E

Could not process the IOCTL(aa). (aa:cc)

Check the message of the HDLM

command or the HDLM manager, and

then take the appropriate action. If you

do not know the appropriate action,

execute the DLMgetras utility to collect

error information, and then contact your

Details

Processing corresponding

to the requested IOCTL

(aa...aa: IOCTL code

(hexadecimal number)) is

unsuccessful.

8-42

Messages

Hitachi Dynamic Link Manager User Guide for AIX®