beautypg.com

Smi-s access failures – HP SAN User Manual

Page 53

background image

SMI-S Access failures

While collecting data through SMI-S for Brocade switches, if there are any connection failures to
the switches or if the SMI agent is stopped, then the data collection falls back to SNMP, and a
report is generated.
For more information, contact HP or visit Servers & Storage expertise center at:

http://www.hp.com/

sbso/serverstorage/index.html

Changing SNMP proxy settings for HP Storage 8/20q and QLogic FC
switches

To change the SNMP proxy setting parameter for HP Storage 8/20q and QLogic FC switches,
complete the following steps:

1.

Login to the switch you want to change the SNMP proxy settings.

2.

Run the admin start command to start the session in admin mode.

3.

Run the following command: set setup snmp.

4.

Set the SNMP proxy parameter (ProxyEnabled) to "False”.

5.

Save and exit from the session.

SMI-S Access failures

53