CHAPTER 9 HP-GL - 9
PU - Pen up
PU [ X,Y [,...]] [;]
X ; X coordinate of the cursor movement destination
Y ; Y coordinate of the cursor movement destination
X and Y are either relative or absolute, depending on whether a PA or a PR was the last plot command
executed. The absolute coordinates are set as default.
Moves the cursor to the specified coordinates after raising the pen.
Using this instruction without a parameter field raises the pen without changing the cursor position.
When scaling is on, user coordinates are used.
Also, when scaling has been performed, the values for X and Y are real numbers.
When scaling is off graphics units are used.
When there is no scaling, the coordinates values for X and Y are integer numbers.
Current position
(X1, Y1)
(X2,Y2)
(X3, Y3)
(Xn, Yn)
PD - Pen down
PD [ X, Y [,...]] [;]
X ; X coordinate of the cursor movement destination
Y ; Y coordinate of the cursor movement destination
X and Y are either relative or absolute, depending on whether a PA or a PR was the last plot command
executed. The absolute coordinates are set as default.
Moves the cursor to the specified coordinates after lowering the pen. (This plots a straight line.)
Using this instruction without a parameter lowers the pen without changing the cursor position. ( One dot is
plotted.)
When scaling has been performed, the cursor is moved by user coordinates.
Also, when scaling has been performed, the values for X and Y are real numbers.
When there is no scaling, the cursor is moved by absolute coordinates in graphics units.
When there is no scaling, the coordinate values for X and Y are integer numbers.
Current position
(X1, Y1)
(X2,Y2)
(X3, Y3)
(Xn, Yn)
PA - Plot absolute
PA [X, Y [,...]] [;]
X ; X coordinate of the cursor movement destination
Y ; Y coordinate of the cursor movement destination
X and Y are absolute values in user units or graphics units.
Moves the cursor to the specified coordinates.
Plots a straight line only when the pen is down.
When scaling has been performed, the values for X and Y are integer numbers.
When there is no scaling, the cursor is moved by absolute coordinates in graphics units.
When there is no scaling, the coordinate values for X and Y are integer numbers.
- HL-1670N HL-6050D HL 5250DN HL-5070N HL-2460 HL-6050DN HL-2150N HL 2700CN HL-2130 HL-S7000DN HL-3040CN HL 1650 HL-6050 HL-5240 HL-5240L HL-1470N HL 3070CW HL 5170DN HL-3450CN HL-3140CW HL 5470DW HL-5140 HL-5440D HL-7050 HL-2240 HL-5040 HL-4070CDW HL-1870N HL-1110 HL-1850 HL 4150CDN HL-8050N HL 5450DN HL 5370DW HL-5050 HL-2140 HL 1270N HL-2600CN HL-6180DW HL-5350DN HL-4050CDN HL-2070N HL-3260N HL-5150D HL-5280DW HL-3170CDW HL-4570CDW HL-3150CDW HL 4040CN HL-4140CN HL 2240D HL 2270DW HL-1250 HL-7050N HL 5340D HL-2250DN HL-1450 HL-L9200CDWT HL-1112 HL-5270DN HL-5450DNT HL-L8250CDN HL 4570CDWT HL-5380DN HL-6180DWT HL-L8350CDW HL-4040CDN HL-L8350CDWT HL-2230 HL-5470DWT HL 2220 HL-1110E HL-1112E