CHAPTER 4 HP-GL/2 - 14
7.2.
Plot Area and Unit Setting Instructions
Instruction Function
IP Scaling
point
IR
Input relative scaling points
SC Scale
IW Input
window
RO
Rotate coordinate system
IP - Input scaling point
IP [ P1
X
, P1
Y
[,P2
X,
P2
Y
]] [;]
P1
X
;
X
coordinate of P1 P1
Y
;
Y
coordinate of P1
P2
X
;
X
coordinate of P2 P2
Y
;
Y
coordinate of P2
The coordinates used are absolute values in graphics units.
Set the location of the scaling points(P1,P2).
Coordinate values for P1X,P1Y, P2X and P2Y are given as integer numbers.
You can set P1 and P2 to be anywhere that the range of allowable coordinates permits. However, only
parts of resulting images that lie within the effective window will be printed.
The default location of P1 is the lower left corner and P2 is the upper right corner of the PCL picture frame.
Using this instruction without a parameter field initializes the scaling points(P1,P2) to the default location.
P2X and P2Y may be omitted. If P2X and P2Y are omitted, P2 is set automatically so as not to alter the
distance between P1 and P2.
If P2x and P2y are omitted P2 is set to be in the same position relative to P1 that it was before the command
was invoked.
The IP command remains in effect until another IP command, an IR command or an IN command is used.
IR - Input relative scaling points
IR [ P1x, P1y [, P2x, P2y]][;]
P1x ; x-coordinate of P1 P1y ; y-coordinate of P1
P2x ; x-coordinate of P2 P2y ; y-coordinate of P2
The coordinate values are percentages relative to the bottom left and top right hand corners of the picture
frame.
Coordinate values for P1x, P1y, P2x, and P2y are treated as clamped real numbers.
Using this instruction without parameters sets the scaling points (P1, P2) to their initial positions, the bottom
left and top right hand corners of the picture frame.
If P2x and P2y are omitted P2 is set to be in the same position relative to P1 that it was before the command
was invoked.
You can set P1 and P2 to be anywhere that the range of allowable coordinates permits. However, only
parts of resulting images that lie within the effective window will be printed.
The IR command remains in effect until another IR command, and IP command or an IN command is used.
- HL-1670N HL-6050D HL 5250DN HL-5070N HL-2460 HL-6050DN HL-2150N HL 2700CN HL-2130 HL-S7000DN HL-3040CN HL 1650 HL-6050 HL-5240 HL-5240L HL-1470N HL 3070CW HL 5170DN HL-3450CN HL-3140CW HL 5470DW HL-5140 HL-5440D HL-7050 HL-2240 HL-5040 HL-4070CDW HL-1870N HL-1110 HL-1850 HL 4150CDN HL-8050N HL 5450DN HL 5370DW HL-5050 HL-2140 HL 1270N HL-2600CN HL-6180DW HL-5350DN HL-4050CDN HL-2070N HL-3260N HL-5150D HL-5280DW HL-3170CDW HL-4570CDW HL-3150CDW HL 4040CN HL-4140CN HL 2240D HL 2270DW HL-1250 HL-7050N HL 5340D HL-2250DN HL-1450 HL-L9200CDWT HL-1112 HL-5270DN HL-5450DNT HL-L8250CDN HL 4570CDWT HL-5380DN HL-6180DWT HL-L8350CDW HL-4040CDN HL-L8350CDWT HL-2230 HL-5470DWT HL 2220 HL-1110E HL-1112E