CHAPTER 4 HP-GL/2 - 37
170 'Source 2
180 LPRINT "FT10,50;PA4000,5000;RR500,500;PA4500,5500;RR500,500;"
190 LPRINT "FT10,1;PA4500,5000;RR500,500;PA4000,5500;RR500,500;FT;"
200 '
210 '( POLYGON )
220 LPRINT "PA2000,1000;PM0;PDPA4000,1000,3000,3000;PM1;"
230 LPRINT "PA2500,1200,3500,1200,3000,2500;PM1;"
240 LPRINT "PA3000,800,3700,2500,2300,2500;PM1;"
250 LPRINT "PM2;FP;"
260 LPRINT CHR$(27); "%0A";
270 LPRINT CHR$(27); "E";
280 END
UL - User-defined line type
UL [ i ] [,g [...,]] [;]
i ; unit type
g : gap length
This command allows you to define line types which you can then subsequently select with the LT
command.
i must be in the range 1-8. i identifies the line type that is to be defined.
The index parameter uses absolute values.
g (the gap length) alternately specifies pen up and pen down parts of the defined line type. A maximum of
twenty line sections are permitted, the first of which is a pen down section. Numbers must be integers in
the range 0~32767. These numbers are converted to percentages by the LT command.
Maximum definition for the gap of each line type is 20.
The sum of the gap parameters must be greater than 0.
Specifying an index number with no gap parameters sets the line type to the default pattern for that index
number.
Using the command with no parameter sets all line types to the defaults.
10 '-User Defined Line Type-
20 WIDTH "LPT1:", 255
30 LPRINT CHR$(27); "E";
40 LPRINT CHR$(27); "%0B";
50 LPRINT "IN;SP1;;"
60 LPRINT "UL8,0,15,0,15,0,15,40,15;"
70 LPRINT "LT8,5;PA2000,2500;PDPA5000,2500;PU;"
80 LPRINT "UL4,40,15,0,15,0,15,40,15,0,15;"
90 LPRINT "LT4,10;PA2000,3000;PDPA5000,3000;PU;"
100 LPRINT "UL1,40,40,40,40,40;"
110 LPRINT "LT1,10;PA2000,3500;PDPA5000,3500;PU;"
120 LPRINT CHR$(27); "%0A";
130 LPRINT CHR$(27); "E";
140 END
WU - Select unit for pen width
WU [ t ] [;]
t ; unit type
This command specifies the pen width unit. It applies to all pens.
t must be either 0 or 1.
If t is 0 the pen width parameter which accompanies subsequent PW commands will be treated as a reading
in millimeters.
If t is 1 the pen width parameter which accompanies subsequent PW commands will be treated as percentage
of the distance between the scaling points P1 and P2. The default width is 0.1% of the diagonal distance
from P1 to P2.
- HL-1670N HL-6050D HL 5250DN HL-5070N HL-2460 HL-6050DN HL-2150N HL 2700CN HL-2130 HL-S7000DN HL-3040CN HL 1650 HL-6050 HL-5240 HL-5240L HL-1470N HL 3070CW HL 5170DN HL-3450CN HL-3140CW HL 5470DW HL-5140 HL-5440D HL-7050 HL-2240 HL-5040 HL-4070CDW HL-1870N HL-1110 HL-1850 HL 4150CDN HL-8050N HL 5450DN HL 5370DW HL-5050 HL-2140 HL 1270N HL-2600CN HL-6180DW HL-5350DN HL-4050CDN HL-2070N HL-3260N HL-5150D HL-5280DW HL-3170CDW HL-4570CDW HL-3150CDW HL 4040CN HL-4140CN HL 2240D HL 2270DW HL-1250 HL-7050N HL 5340D HL-2250DN HL-1450 HL-L9200CDWT HL-1112 HL-5270DN HL-5450DNT HL-L8250CDN HL 4570CDWT HL-5380DN HL-6180DWT HL-L8350CDW HL-4040CDN HL-L8350CDWT HL-2230 HL-5470DWT HL 2220 HL-1110E HL-1112E