For instance, a font extended response with the location type set to 1( selected at present ) where the font which
is selected at present is the internal Pc Tennessee (18 point identified for printing) bold, returns the response as
follows.
PCL
INFO FONTS EXTENDED
SELECT="
DEFID="
DEFID="I 2"
NAME="PcTennessee Bd"
LOCTYPE=1
LOCUNIT=1
8.5.12.
Macro response
The status response for macros indicates all of the macro IDs ("IDLIST=") for the macros in a particular
location.
Status location type 1( selected at present ) is an unused location for macros and an error is returned.
A macro status response may be shown as follows.
PCL
INFO MACROS
IDLIST="1, 3, 8, 29, 32"
8.5.13.
Use-defined pattern response
The status response of user-defined patterns indicates all of the user-defined patterns and all of the user-defined
pattern IDs ("IDLIST") for the patterns in a particular location.
A user-defined pattern response may be shown as follows.
PCL
INFO PATTERN
IDLIST="1, 2, 9, 13, 27, 456"
When the location type is specified to 1 (selected at present), "LOCTYPE=" and "LOCUNIT=" lines are added.
It returns the "LOCTYPE=" only for a status location type 1 requirement. It specifies the location type of the
pattern which is selected at present.
It returns the "LOCUNIT=" only for a status location type 1 requirement. It specifies the location unit of the
pattern which is selected at present.
A user-defined pattern response for the pattern selected at present may be shown as follows.
PCL
INFO PATTERN
IDLIST="88"
LOCTYPE=4
LOCUNIT=2
When the pattern selected at present is set to one of the internal HP-specified patterns, there is no number
available and it returns the response "ERROR=NONE".
PCL
INFO PATTERNS
ERROR=NONE
8.5.14.
Symbol set response
The symbol set response indicates all of the symbol set IDs ("IDLIST") for all of the symbol sets in the
identified location. There can be bound and unbound scalable fonts in the identified location (type and unit).
A symbol set response may be shown as follows.
PCL
INFO SYMBOLSETS
IDLIST="0U, 2K, 8M, 11U"
- HL-1670N HL-6050D HL 5250DN HL-5070N HL-2460 HL-6050DN HL-2150N HL 2700CN HL-2130 HL-S7000DN HL-3040CN HL 1650 HL-6050 HL-5240 HL-5240L HL-1470N HL 3070CW HL 5170DN HL-3450CN HL-3140CW HL 5470DW HL-5140 HL-5440D HL-7050 HL-2240 HL-5040 HL-4070CDW HL-1870N HL-1110 HL-1850 HL 4150CDN HL-8050N HL 5450DN HL 5370DW HL-5050 HL-2140 HL 1270N HL-2600CN HL-6180DW HL-5350DN HL-4050CDN HL-2070N HL-3260N HL-5150D HL-5280DW HL-3170CDW HL-4570CDW HL-3150CDW HL 4040CN HL-4140CN HL 2240D HL 2270DW HL-1250 HL-7050N HL 5340D HL-2250DN HL-1450 HL-L9200CDWT HL-1112 HL-5270DN HL-5450DNT HL-L8250CDN HL 4570CDWT HL-5380DN HL-6180DWT HL-L8350CDW HL-4040CDN HL-L8350CDWT HL-2230 HL-5470DWT HL 2220 HL-1110E HL-1112E