beautypg.com

4 information parameters (p700) – NORD Drivesystems BU0220 User Manual

Page 48

background image

PROFIBUS DP

– Supplementary manualfor NORD Frequency Inverter SK 2xxE

48

Subject to technical amendments

BU 0220 GB-0912

5.1.4

Information parameters (P700)

Parameter

Setting value / Description / Note

Device

Supervisor

Parameter
set

P700

Actual error

0.0 ... 21.4

Actual error present. Further details are described in the frequency inverter manual (BU0200).

SimpleBox: Descriptions of the individual error numbers can be found in the point Error
messages.

ParameterBox: Errors are displayed in plain text, further information can be found in the point
Error messages.

P701

... [-01]

...

... [-05]

Last fault 1...5

0.0 ... 21.4

This parameter stores the last 5 faults. Further details are described in the frequency inverter
manual (BU0200).

With the SimpleBox the corresponding memory location 1...5 (Array parameter), must be
selected and confirmed with the ENTER key in order to read the stored error code.

P740

... [-01]

... [-13]

Process data bus In

S

0000 ... FFFF (hex)

This parameter provides information about the actual control word (STW) and the setpoints
(SW1-3) that are transferred via the bus systems.

For values to be displayed, a bus system must be selected in P509.

… [-01 ] = Control word

Control word, source from P509.

… [-02 ] = Setpoint 1 (P546 [-01])

… [-03 ] = Setpoint 2 (P546 [-02])

… [-04 ] = Setpoint 3 (P546 [-03])

Setpoint data from main setpoint P510 - 01.

… [-05 ] = Bus I/O In Bits (P480)

The displayed value depicts all Bus In Bit sources
linked with or.

… [-06 ] = Parameter data In 1

… [-07 ] = Parameter data In 2

… [-08 ] = Parameter data In 3

… [-09 ] = Parameter data In 4

… [-10 ] = Parameter data In 5

Data during parameter transfer: Order label (AK),
Parameter number (PNU),
Index (IND), Parameter value (PWE 1/2)

… [-11 ] = Setpoint 1

… [-12 ] = Setpoint 2

… [-13 ] = Setpoint 3

Setpoint

data

from

master

function

value

(Broadcast), if P509/510 = 4 (P502/P503)