NORD Drivesystems BU0220 User Manual
Page 39
BU 0220 GB-0912
Subject to technical amendments
39
4.2.2.4 Profibus I/O Modules
This setting variant is exclusively reserved for the PROFIBUS DP module SK CU4-PBR or SK TU4-
PBR…)
which is connected to the system bus. This setting enables the DP master to directly access the digital I/Os of
the module. In this 1 byte module, the digital outputs must be set as "output byte" and the digital inputs as
"input byte".
The "Profibus module I/O" must always be set to Slot 1 in the DP slave.
If the additional I/Os are not used, an "empty module" must be set on Slot 1.
The bits are allocated to the inputs and outputs as follows:
NOTE
The digital inputs of the PROFIBUS DP modules (SK CU4-PBR and SK TU4-PBR-
…) cannot
be directly assigned with frequency inverter functionalities. These must be transferred via the
PROFIBUS and can be returned to the frequency inverter from the bus master via bits 8 and 9
of the control word by assignment of the required function in the BUS I/O In bits (P480 [-11] or
[-12]).
PLC I/Os
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Inputs
n. c.
n. c.
n. c.
n. c.
DIN4
DIN3
DIN2
DIN1
Outputs
n. c.
n. c.
n. c.
n. c.
n. c.
n. c.
DO2
DO1