TECHNICAL DATA

86

H250

www.krohne.com

04/2011 - 4000269302 MA H250-R02 en

H250U - Vertical installation position

Reference condition for gas measurements:

Reference condition for gas measurements:

Reference condition for gas measurements:

Reference condition for gas measurements:
The flow measurement of gases are refered to
Nl/h or Nm

3

/h: Volume flow in Normal state 0°C, 1.013 bar abs. (DIN 1343)

Measuring span:

10 : 1

Declaration of flow:

Values = 100%

Water: 20°C [68°F]

Air: 20°C [68°F], 1.013 bar abs. [14.7 psia]

Flow direction

from top to bottom

EN

ASME

Cone

Water [l/h]

Air [Nm

3

/h]

Pressure loss

[mbar]

DN15

½

"

K 15.1

65

1.6

175

K 15.2

110

2.5

178

K 15.3

170

4

180

K 15.4

260

6

200

K 15.5

420

10

220

K 15.6

650

16

290

K 15.7

1100

28

520

K 15.8

1500

40

840

DN25

1"

K 25.1

1150

30

97

K 25.2

1800

45

85

K 25.3

2700

70

92

K 25.4

4500

120

115

K 25.5

7600

200

172

DN50

2"

K 55.1

9000

240

220

K 55.2

15000

400

230

K 55.3

21000

550

240

INFORMATION!
The oper. press. should be at least twice the pressure loss for liquids, and at least 5
times the pressure loss for gases! The specified pressure drops are valid for water and air at
maximum flow rate. Other flow ranges on request. Conversion of other media or operating data
(pressure, temperature, density, viscosity) is performed using the calculation method in
accordance with VDI /VDE Directive 3513