Technical data – KROHNE H250 M8-M9-M10 EN User Manual
Page 79

TECHNICAL DATA
8
79
H250
www.krohne.com
04/2011 - 4000269302 MA H250-R02 en
Bolts and tightening torques
For flowmeters with PTFE liner or ceramic liner and PTFE raised face, tighten the flange threads
with the following torques:
Nominal sizes EN
Nominal size ASME
Low pressure resistance (vacuum) H250/C
Nominal size
Bolts
Tightening torques
acc. to EN 1092-1
Quantity x size
[Nm]
[lb-ft]
DN15 PN40
1
4 x M 12
9.8
7.1
DN25 PN40
1
4 x M 12
21
15
DN50 PN40
1
4x M16
57
41
DN80 PN16
1
8x M16
47
34
DN100 PN16
1
8x M16
67
48
1 standard connections; other connection on request
Nominal size
Bolts (Quantity x size)
Tightening torques
acc. to ASME B 16.5
150 lb
300 lb
[Nm]
[lb-ft]
½
" 150 lb / 300 lb
1
4x ½"
4x ½"
5.2
3.8
1" 150 lb / 300 lb
1
4x ½"
4x 5/8"
10
7.2
2" 150 lb / 300 lb
1
4x 5/8"
8x 5/8"
41
30
3" 150 lb / 300 lb
1
4x 5/8"
8x ¾"
70
51
4" 150 lb / 300 lb
1
8x 5/8"
8x ¾"
50
36
1 standard connections; other connections on request
Max. process temperature +70°C (+158°F)
+150°C (*302°F) +250°C (+482°F)
Min. operating pressure
Nominal size
float
lining
[mbar
abs.]
[psia]
[mbar
abs.]
[psia]
[mbar
abs.]
[psia]
DN15...DN100
PTFE
PTFE
100
1,45
-
-
-
-
DN15...DN80
ceramic
PTFE
100
1,45
250
3,63
-
-
DN15...DN80
ceramic
TFM /
ceramic
100
1,45
100
1,45
100
1,45
MA_H250_R02_en_269302_PRT.book Page 79 Tuesday, April 12, 2011 10:17 AM