Take special note of the installation position for the H250H with horizontal flow
direction:

In order to comply with thermal parameters and measuring accuracy, H250H flowmeters for
horizontal installation are to be installed in the pipeline so that the display is located on the side
of the measuring tube. The maximum medium and ambient temperatures indicated as well as
the measuring accuracy are based on lateral installation of the display.

3.3.1 Tightening torques

For measuring devices with PTFE liner or ceramic liner and PTFE raised face, tighten the flange
threads with the following torques:

Nominal size acc. to

Bolts

Max. torque

EN 1092-1

ASME B16.5

EN

1092-1

ASME

EN 1092-1

ASME 150 lb

DN

PN

Inches

lb

150 lb

300 lb

Nm

ft*lbf

Nm

ft*lbf

15

40

½

"

150/300

4 x M 12

4 x ½"

4 x ½"

9.8

7.1

5.2

3.8

25

40

1"

150/300

4 x M 12

4 x ½" 4 x 5/8"

21

15

10

7.2

50

40

2"

150/300

4 x M 16 4 x 5/8" 8 x 5/8"

57

41

41

30

80

16

3"

150/300

8 x M 16 4 x 5/8"

8 x ¾"

47

34

70

51

100

16

4"

150/300

8 x M 16 8 x 5/8"

8 x ¾"

67

48

50

36

MA_H250_R02_en_269302_PRT.book Page 17 Tuesday, April 12, 2011 10:17 AM