beautypg.com

Technical data – KROHNE H250 M8-M9-M10 EN User Manual

Page 83

background image

TECHNICAL DATA

8

83

H250

www.krohne.com

04/2011 - 4000269302 MA H250-R02 en

H250/C - Ceramic/PTFE

Reference condition for gas measurements:

Reference condition for gas measurements:

Reference condition for gas measurements:

Reference condition for gas measurements:
The flow measurement of gases are refered to
SCFM or SCFH: Volume flow in Standard state 15°C, 1.013 bar abs. (ISO 13443)

Measuring span:

10 : 1

Declaration of flow:

Values = 100%

Water: 20°C [68°F]

Air: 20°C [68°F], 1.013 bar abs. [14.7 psia]

Flow rate

Max. pressure loss

Water

Air

Water

Air

Liner / Float

PTFE

Ceramic

Ceramic

PTFE

Ceramic

Ceramic

Nominal

size

Cone

[GPH]

[SCFM]

[psig]

DN15, ½"

E 17.2

6.60

7.93

-

0.96

0.91

0.91

E 17.3

10.6

13.2

1.12

0.97

0.94

0.94

E 17.4

16.6

18.5

1.49

0.97

0.97

0.97

E 17.5

26.4

34.3

2.48

1.00

1.00

1.00

E 17.6

42.3

52.8

4.03

1.06

1.03

1.03

E 17.7

66.0

66.0

5.58

1.26

1.06

1.06

E 17.8

106

-

-

1.63

-

-

DN25, 1"

E 27.1

166

132

11.2

1.03

0.81

0.81

E 27.2

264

185

13.6

1.18

0.88

0.88

E 27.3

423

291

18.6

1.59

1.03

1.03

E 27.4

660

423

31.0

2.32

1.21

1.21

E 27.5

1056

1

660

46.5

4.26

1.47

1.47

DN50, 2"

E 57.1

1057

1189

86.8

1.19

1.03

1.03

E 57.2

1664

1664

124

1.62

1.18

1.18

E 57.3

2642

2906

217

2.50

1.62

1.62

E 57.4

4226

1

-

-

4.17

-

-

DN80, 3"

E 87.1

4227

4227

-

1.19

1.03

-

E 87.2

6604

6604

-

1.40

1.25

-

E 87.3

10567

1

-

-

3.57

-

-

DN100, 4"

E 107.1

10567

-

-

1.47

-

-

E 107.2

15850

1

-

-

3.31

-

-

1 special float

INFORMATION!
The oper. press. should be at least twice the pressure loss for liquids, and at least 5
times the pressure loss for gases! The specified pressure drops are valid for water and air at
maximum flow rate. Other flow ranges on request. Conversion of other media or operating data
(pressure, temperature, density, viscosity) is performed using the calculation method in
accordance with VDI /VDE Directive 3513

MA_H250_R02_en_269302_PRT.book Page 83 Tuesday, April 12, 2011 10:17 AM