Limit setting

Setting is carried out directly via contact pointers 1 and 2:

• Slide the scale away
• Loosen the locking screw 3 slightly
• Slide the scale back to the latching point
• Set contact pointers 1 and 2 to the desired switching point

After setting has been carried out: Fix the contact pointers with the locking screw 3.

Limit switch connection terminals

1 2-wire limit switch NAMUR
2 3-wire limit switch
3 Terminal connection min contact
4 Terminal connection max contact
5 3-wire load
6 NAMUR isolated switching amplifier
7 3-wire power supply

Figure 4-4: Limit switch settings

1 Contact pointer MAX
2 Contact pointer MIN