beautypg.com

Technical data – KROHNE H250 M8-M9-M10 EN User Manual

Page 81

background image

TECHNICAL DATA

8

81

H250

www.krohne.com

04/2011 - 4000269302 MA H250-R02 en

H250/RR - Stainless Steel, H250/HC - Hastelloy

®

Reference condition for gas measurements:

Reference condition for gas measurements:

Reference condition for gas measurements:

Reference condition for gas measurements:
The flow measurement of gases are refered to
SCFM or SCFH: Volume flow in Standard state 15°C, 1.013 bar abs. (ISO 13443)

Measuring span:

10 : 1

Declaration of flow:

Values = 100%

Water: 20°C [68°F]

Air: 20°C [68°F], 1.013 bar abs. [14.7 psia]

Water

Air

Max. pressure loss

Float TIV

CIV

DIV

TIV

Alu

TIV

DIV

TIV

Alu

TIV

CIV

DIV

Nominal

size

Cone

[GPH]

[SCFM]

[psig]

DN15, ½"

K 15.1

4.76

6.60

-

0.26

0.43

-

0.18

0.31

0.38

-

K 15.2

7.93

10.6

-

0.43

0.62

-

0.18

0.31

0.38

-

K 15.3

14.5

16.6

-

0.62

0.93

-

0.18

0.31

0.38

-

K 15.4

21.1

26.4

-

1.05

1.36

-

0.18

0.31

0.38

-

K 15.5

31.7

42.3

-

1.55

2.23

-

0.18

0.31

0.38

-

K 15.6

52.8

66.0

-

2.60

3.41

-

0.18

0.31

0.38

-

K 15.7

92.5

106

185

4.15

6.20

11.2

1

0.18

0.31

0.41

0.56

K 15.8

132

166

264

6.20

8.68

17.4

1

0.19

0.32

0.47

0.74

K 15.8

-

-

423

2

-

-

31.0

2

-

-

-

1.25

DN25, 1"

K 25.1

127

166

264

5.89

8.68

-

0.16

0.35

0.47

1.06

K 25.2

217

264

423

9.30

14.3

-

0.16

0.35

0.49

1.09

K 25.3

317

423

660

13.6

21.7

-

0.16

0.37

0.50

1.10

K 25.4

449

660

1057

22.9

31.0

68.2

1

0.18

0.38

0.56

1.15

K 25.5

845

1057

1664

38.4

58.9

111

1

0.19

0.44

0.66

1.51

3

DN50, 2"

K 55.1

713

1664

2219

36.0

49.6

143

1

0.12

0.19

1.09

0.88

K 55.2

951

2642

3698

47.7

68.2

217

1

0.12

0.19

1.13

1.01

K 55.3

1347

4227

6604

68.2

93.0

434

1

0.13

0.19

1.23

1.53

DN80, 3"

K 85.1

3170

6604

9774

152

217

620

1

0.12

0.24

1.00

1.40

K 85.2

4227

10567

16907

174

248

1116

1

0.13

0.24

1.31

1.84

DN100, 4" K105.1

5019

16643

26418

-

341

1736

1

-

1.76

3.23

1 P >7.4 psig
2 with TR float
3 4.4 psig with damping (gas measurement)

INFORMATION!
The oper. press. should be at least twice the pressure loss for liquids, and at least 5
times the pressure loss for gases! The specified pressure drops are valid for water and air at
maximum flow rate. Other flow ranges on request. Conversion of other media or operating data
(pressure, temperature, density, viscosity) is performed using the calculation method in
accordance with VDI /VDE Directive 3513

MA_H250_R02_en_269302_PRT.book Page 81 Tuesday, April 12, 2011 10:17 AM