Technical data, 4 measuring ranges – KROHNE H250 M8-M9-M10 EN User Manual
Page 80
8
TECHNICAL DATA
80
H250
www.krohne.com
04/2011 - 4000269302 MA H250-R02 en
8.4 Measuring ranges
H250/RR - Stainless Steel, H250/HC - Hastelloy
®
Reference condition for gas measurements:
Reference condition for gas measurements:
Reference condition for gas measurements:
Reference condition for gas measurements:
The flow measurement of gases are refered to
Nl/h or Nm
3
/h: Volume flow in Normal state 0°C, 1.013 bar abs. (DIN 1343)
Measuring span:
10 : 1
Declaration of flow:
Values = 100%
Water: 20°C [68°F]
Air: 20°C [68°F], 1.013 bar abs. [14.7 psia]
Water
Air
Max. pressure loss
Float
TIV
CIV
DIV
TIV
Alu
TIV
DIV
TIV
Alu
TIV
CIV
DIV
Nominal
size
Cone
[l/h]
[Nm
3
/h]
[mbar]
DN15, ½"
K 15.1
18
25
-
0.42
0.65
-
12
21
26
-
K 15.2
30
40
-
0.7
1
-
12
21
26
-
K 15.3
55
63
-
1
1.5
-
12
21
26
-
K 15.4
80
100
-
1.7
2.2
-
12
21
26
-
K 15.5
120
160
-
2.5
3.6
-
12
21
26
-
K 15.6
200
250
-
4.2
5.5
-
12
21
26
-
K 15.7
350
400
700
6.7
10
18
1
12
21
28
38
K 15.8
500
630
1000
10
14
28
1
13
22
32
50
K 15.8
-
- 1600
2
-
-
50
2
-
-
-
85
DN25, 1"
K 25.1
480
630
1000
9.5
14
-
11
24
32
72
K 25.2
820
1000
1600
15
23
-
11
24
33
74
K 25.3
1200
1600
2500
22
35
-
11
25
34
75
K 25.4
1700
2500
4000
37
50
110
1
12
26
38
78
K 25.5
3200
4000
6300
62
95
180
1
13
30
45
103
3
DN50, 2"
K 55.1
2700
6300
8400
58
80
230
1
8
13
74
60
K 55.2
3600
10000
14000
77
110
350
1
8
13
77
69
K 55.3
5100
16000
25000
110
150
700
1
9
13
84
104
DN80, 3"
K 85.1
12000
25000
37000
245
350
1000
1
8
16
68
95
K 85.2
16000
40000
64000
280
400
1800
1
9
16
89
125
DN100, 4"
K105.1
19000
63000 100 000
-
550
2800
1
-
-
120
220
1 P >0.5 bar
2 with TR float
3 300 mbar with damping (gas measurement)
INFORMATION!
The oper. press. should be at least twice the pressure loss for liquids, and at least 5
times the pressure loss for gases! The specified pressure drops are valid for water and air at
maximum flow rate. Other flow ranges on request. Conversion of other media or operating data
(pressure, temperature, density, viscosity) is performed using the calculation method in
accordance with VDI /VDE Directive 3513
MA_H250_R02_en_269302_PRT.book Page 80 Tuesday, April 12, 2011 10:17 AM