TECHNICAL DATA

66

H250

www.krohne.com

04/2011 - 4000269302 MA H250-R02 en

Materials

Other options:

• Special materials on request: e.g. SMO 254, titanium, 1.4435
• Float damping: ceramic or PEEK
• Gasket for devices with female thread as insert: O-ring FPM / FKM

Temperatures

Temperatures

Temperatures

Temperatures

Temperatures H250/M9 - mechanical indicator without power supply

Device

Flange / raised face Measur.

tube

Float

Float stop /
guide

Ring orifice

H250/RR

Stainless Steel

CrNi steel 1.4404

massive

1

CrNi steel 1.4404

1

-

H250/HC
Hastelloy

®

CrNi steel 1.4571 with
plated Hastelloy

®

C4

(2.4610)

1

Hastelloy

®

C4 (2.4610)

-

H250/C

Ceramic/PTFE

CrNi-Stahl 1.4571

with TFM/PTFE liner

2

PTFE or Al

2

O

3

with FFKM

gasket

Al

2

O

3

and PTFE

Al

2

O

3

H250/F - Food

CrNi-Stahl 1.4435

-

1 CrNi steel 1.4571 on request, for clamp connection CrNi steel 1.4435
2 TFM/PTFE liner (electrically non-conductive)

INFORMATION!
H250/C - DN100 / 4" only PTFE
H250/F: wetted surfaces Ra ≤0.8 μm, optional ≤0.6 μm

DANGER!
For devices to be used in hazardous areas, special temperature ranges apply. These can be
found in the separate instructions.

Float

Liner

Product temperature

Ambient temperature

[°C]

[°F]

[°C]

[°F]

H250/RR

Stainless Steel

-196...+300

-321...+572

-40...+120

-40…+248

H250/RR screw fitting

-20…+120

-4…+248

H250/HC

Hastelloy

®

C4

-196...+300

-321...+572

-40...+120

-40…+248

H250/C

PTFE

PTFE

-196...+70

-321...+158

-40...+70

-40…+158

H250/C

Ceramic

PTFE

-196...+150

-321...+302

-40...+70

-40…+158

H250/C

Ceramic

TFM / Ceramic

-196...+250

-321...+482

-40...+120

-40…+248

H250 H/U

Stainless Steel

-40...+100

-40…+212

-20…+90

-4…+194

MA_H250_R02_en_269302_PRT.book Page 66 Tuesday, April 12, 2011 10:17 AM