beautypg.com

Technical data – KROHNE H250 M8-M9-M10 EN User Manual

Page 73

background image

TECHNICAL DATA

8

73

H250

www.krohne.com

04/2011 - 4000269302 MA H250-R02 en

Indicator M10

Indicator M10

Indicator M10

Indicator M10

M10 cable gland

(Standard)

without

M20 x 1.5

On request

M 20x1.5 Ex d

On request

M10 current output

Terminal connection

2.5 mm

2

Power supply

24 VDC ±30%

Min. power supply for HART

®

18 VDC

Measuring signal

4.00...20.00 mA = 0...100% flow value in 2-wire technology

Power supply influence

< 0.1%

Dependence on external resistance

< 0.1%

Temperature influence

< 5 µA/K

Max. external resistance / load

≤ 630 Ohm

Min. load for HART

≥ 250 Ohm

Software firmware version

02.17

Ident No.

3209470500

M10 HART

®

Manufacturer name (code)

KROHNE Messtechnik (69 = 45h)

Model name

M10 (234 = EA)

HART

®

protocol revision

5.9

Device revision

1

Physical layer

FSK

Device category

Transmitter

M10 process variable

Values [%]

Signal output [mA]

Over range

+105 (±1%)

20,64...20.96

Device error identification

> 110

> 21.60

Maximum

112.5

22

Multidrop operation

-

4.5

Lift-off voltage

12 VDC

MA_H250_R02_en_269302_PRT.book Page 73 Tuesday, April 12, 2011 10:17 AM